FTLSW-1000AP Ophthalmic A-Scan & Pachymeter

Short Description
The FTLSW-1000AP is a professional ophthalmic A-scan and pachymeter system designed for axial length measurement, intraocular lens calculation, and corneal thickness measurement. It combines a 10MHz A-scan probe with a 20MHz pachymetry probe for comprehensive ophthalmic examination.

[oneclick single="true" phone="+8801335129750" product="current" text="Inquire On WhatsApp" message="Hello, I need to know more about this Product." fullwidth="false"]

Descriptions

Full Product Description
The FTLSW-1000AP A-Scan & Pachymeter is designed for accurate biometric and corneal measurements in ophthalmology clinics and diagnostic centers. The A-scan module provides a measuring range of 15–40mm with measurement precision of approximately ±0.05mm and supports anterior chamber depth, lens thickness, vitreous body length, total axial length, and average measurements. Multiple eye modes and IOL calculation formulas provide flexibility for pre-operative assessment. The pachymetry function uses a 20MHz probe with approximately 5μm resolution and a measuring range of 150–1500μm, making it suitable for corneal thickness evaluation.

Key Features
• Combined A-scan and pachymeter system
• 10MHz A-scan probe
• Built-in probe illumination
• 20MHz pachymetry probe
• Axial length measurement
• Anterior chamber depth measurement
• Lens thickness measurement
• Vitreous body length measurement
• Corneal thickness measurement
• Contact and immersion measurement methods
• Multiple eye condition modes
• Multiple IOL calculation formulas
• Macula lutea trace function
• Single and mapping display modes
• Suitable for cataract and ophthalmic biometric evaluation

Specifications

Model: FTLSW-1000AP
Product Type: Ophthalmic A-Scan & Pachymeter

A-Scan Specifications:
Probe Frequency: 10MHz
Measuring Range: 15–40mm
Measurement Precision: ±0.05mm
Measurement Parameters: Anterior Chamber Depth / Lens Thickness / Vitreous Body Length / Total Axial Length / Average
Measurement Method: Immersion / Contact
Eye Modes: Phakic / Aphakic / Dense / Various IOL Modes
IOL Formulas: SRK-II / SRK-T / BINKHORST-II / Holladay / Hoffer-Q / Haigis
Macula Lutea Trace Function: Yes
Built-In Probe Illumination: Yes

Pachymeter Specifications:
Probe Frequency: 20MHz
Probe Angle: 45°
Resolution: 5μm
Measuring Range: 150–1500μm
Display Mode: Single / Mapping
Application: Corneal Thickness Measurement

Application: Ophthalmic Biometry / IOL Calculation / Corneal Pachymetry
Recommended Use: Eye Clinic / Ophthalmology Department / Diagnostic Center